SMA Sunny Boy SB 3000-US Grid-Tie String Inverter


    SMA SKU#: SB 3000US-10
    • Estimated Shipping: 5 Days
    • Minimum Quantity Order:
    • Note:
    Price: Please, login or register to see prices.
    Don't see prices? Click here to register or Sign In
    ?Why add to quote?
    Build Your Own Quote
    This is helpful so you can re-use the same product list for quotes in the future that are similar to this project.
    • Sell Item Like This
    You must be logged in to sell a product like this.
    SMA Sunny Boy SB 3000-US Grid-Tie String Inverter


    UL certified, reliable system managers

    The Sunny Boy 3000-US, 3800-US and 4000-US inverters are specially designed for countries that require UL certification. Automatic grid voltage detection* and an integrated DC disconnect switch simplifies installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules-crystalline as well as thin-film. The die-cast aluminum enclosure, with the OptiCool active temperature management system, guarantees the highest yields possible and a long service life, even under extreme conditions. The Sunny Boy 3800-US is designed for projects with a current limit of 16A.


    Certifications
    • For countries that require UL certification (UL 1741/IEEE 1547)
    • Optional integrated AFCI functionality meets the requirements of NEC 2011 690.11


    Efficient
    • 96.8% peak efficiency
    • OptiCool™ active temperature management system


    Safe
    • Galvanic isolation


    Simple
    • Patented automatic grid voltage detection*
    • Integrated DC disconnect switch

     

    Assembled in the USA
    • Compliant with ARRA "Buy American" clause

    • Characteristics
    • ManufacturerSMA
    • ModelSB 3000US-10
    • Rated Power Output [W]3000
    • Length [mm (in)]350 mm (14 in)
    • Width [mm (in)]450 mm (18 in)
    • Depth [mm (in)]235 mm (9 in)
    • Weight [kg (lb)]38 kg (84 lb)
    • Warranty [Years]10
    • Surge/Lightning Protection
    • Maximum Volts [Vdc]
    • Discharge Current [kA]
    • Nominal DC Voltage Range [Vdc]
    • Nominal AC Voltage [Vac]
    • Modules
    • Tier Level
    • Lower Output Tolerance [-%]
    • Upper Output Tolerance [%]
    • Only suitable for transformer invertersNo
    • Pmax - Maximum Power (STC) [W]
    • Voc - Open Circuit Voltage (STC) [V]
    • Isc - Short Circuit Current (STC) [A]
    • Vmpp-Voltage at Maximum Power (STC) [V]
    • Impp-Current at Maximum Power (STC) [A]
    • Cell Efficiency (STC) [%]
    • Module Efficiency (STC) [%]
    • Pmax - Maximum Power (NOCT) [W]
    • Voc - Open Circuit Voltage (NOCT) [V]
    • Isc - Short Circuit Current (NOCT) [A]
    • Impp-Current at Maximum Power (NOCT) [A]
    • Vmpp-Voltage at Maximum Power (NOCT) [V]
    • Cell Efficiency (NOCT) [%]
    • Module Efficiency (NOCT) [%]
    • Nominal Operating Cell Temperature NOCT
    • Maximum System Voltage [V]
    • Series Fuse Rating [A]
    • Maximum Reverse Current [A]
    • Cell Technology
    • Solar Cell's Country of Origin
    • Solar Cell Size
    • Number of Cells (Pieces)
    • Number of Bypass Diodes
    • Frame Color
    • Back Cover
    • Junction Box
    • Output Cables
    • Connector
    • Hail Safety Impact Velocity [mm at m/s]
    • Fire Safety Classification (IEC 61730)
    • Static Load Wind / Snow [Pa]
    • Normal Operating Cell Temperature (NOCT)
    • Temperature Coefficients of P [%/°C]
    • Temperature Coefficients of V (Uoc)
    • Temperature Coefficients of I (Isc)
    • Storage Temperature [°C]
    • Packaging Configuration
    • Loading Capacity (40 ft. Container)
    • 80% Power Output Warranty Period
    • 90% Power Output Warranty Period
    • Workmanship Warranty Period
    • CSI Listed
    • Inverters
    • Inverter TypeGrid-Tie String Inverter
    • Maximum/Peak Efficiency [%]208V:96%/ 240V:96.5%
    • CEC weighted efficiency [%]208V:95%/ 240V:95.5%
    • Transformer / TransformerlessTransformer
    • DC Power Rating [W]3000
    • Nom. DC Voltage [V]250
    • Max. Input Power [W]3200
    • Max. Input Voltage [V]500
    • Max. Input Current [A]17 A/17 A; 36 A @ combined terminal
    • MPP voltage range [V]208V: 175 - 400V / 240V: 200-400V
    • Min. DC voltage / start voltage [V]208V:175/228V; 240V:200/228V
    • Feed-in From [W]
    • Number of DC String Inputs (Inlets)4
    • Number of MPP Trackers1
    • Max. Input Power per MPPT [W]
    • Max. Input Voltage per MPPT [V]
    • Max. Input Current per MPPT [A]
    • Voltage Lower Limit for MPP Range [V]208V: 175V / 240V: 200V
    • Voltage Upper Limit for MPP Range [V]208V, 240V: 400V
    • DC Disconnection TypeFused
    • Reverse-Polarity ProtectionNo
    • Ground-Fault Isolation Detection
    • AC Power Rating [W]3000
    • Nominal AC Power [W]3000
    • Max. AC Power [W]3000
    • AC voltage range [V]208V: 183-229V / 240V: 211-264V
    • AC grid frequency [Hz]60
    • Max. output current [A]208V:15A/ 240V: 13A
    • Nominal AC Voltage [V]
    • Maximum AC Voltage Range [V]208V: 229V/ 240V: 264V
    • Nominal AC Frequency [Hz], range [Hz-Hz]
    • Max. AC Line Current [A]
    • AC Connection Type
    • AC Current Distortion [THD%]
    • AC DisconnectYes
    • AC Input Wire Gauge Range [AWG]
    • Max Microinverters Units per xA string
    • Sleep (Night) Consumption [W].1
    • Standby Consumption [W]
    • CSI-Approved Built-in MeterYes
    • NEMA Enclosure RatingNEMA 3R
    • Cooling MethodOptiCool
    • Ambient Temperature Range [°C(°F)]-25°C - 45°C (-13°F - 113°F)
    • Operating Humidity [%]
    • Operating Altitude [ft/m]
    • DisplayText Line
    • CommunicationRS485/Bluetooth optional
    • Basic Warranty [Years]10
    • Warranty Extension Options [Years]15, 20
    • Safety and EMC Standard
    • Grid StandardIEEE1547
    • CompliancesUL1741 (Second Ed.), UL1998, UL1699B, FCC Part 15 (Class A & B), CSA C22.2 No. 107.1-2001
    • AC grid range [Hz]59.3-60.5 Hz
    • Max. recommended PV power (@ module STC)3750
    • Fuses and Holders
    • Amps [A]
    • Data Logers
    • Bluetooth (BT)No
    • WiFi (wireless LAN)No
    • Powermanagement (PM+)No
    • Powermanagement (PM+) / GPRSNo
    • Powermanagement (PM+) / WiFiNo
    • GPRSNo
    • Central inverter SCB and SMBNo
    • Max. no. inverters
    • Communication interface
    • Inverter mixed operationNo
    • Measured max. plant size [kWp]
    • Max. cable length
    • String monitoring-depends on inv. modelNo
    • Inverter failureNo
    • Performance monitoring for each inverterNo
    • Status/fault monitoringNo
    • Connection to sensor systemNo
    • Connection to Sensor BasicNo
    • Email and SMS alarmNo
    • Local alarm (pot. free contact)No
    • Yield forecastingNo
    • Degradation calculationNo
    • Connection to digital meter readerNo
    • Integrated webserverNo
    • Graphic visualisation - local PCNo
    • Graphic visualisation - USB stickNo
    • Graphic visualisation - internetNo
    • LED status displayNo
    • Operation on deviceNo
    • Large display RS485/S0 pulseNo
    • Sâ‚€ in/out
    • Ethernet networkNo
    • USB stickNo
    • Analogue modem / GPRS(GSM)No
    • Potential-free contact (relay)No
    • Alarm contact (anti-theft)No
    • Mains voltage / device voltage [Vac/Vdc]
    • Power consumption [W]
    • Ambient Temperature [°C(°F)]
    • Assembly
    • Protection class for logger
    • Connection to Solar-LogTM WEBNo
    • Multilingual (DE, EN, ES, FR, IT, NL)No
    • Memory
    • Connectors
    • Pre-configured (p), Configurable (c)
    • Test Specifications
    • LockableNo
    • Protection Type Connected / Disconnected
    • Approved Temperature Range [°C]
    • Rated Current, Specified Cable Cross-sec
    • Contact Resistance [mΩ]
    • Max. System DC Voltage [V]
    • Protection Class
    • Contact Material
    • Plug Face is Similar to
    • Combinable w original type confirmed by
    • Measurements (length x cross-section)
    • Combiners
    • Usable Cable Cross-section
    • Number of Breakers
    • Number of Fuse Holders
    • Combiner Voltage Rating (VDC)
    • Combiner Maximum DC Current (A)
    • Max. Input Short Cir. Current/String [A]
    • Maximum Continuous Current (A)
    • Max. Input Current Per String (A)
    • Combiner Maximum Voltage (VDC)
    • Combiner Positive Output Wire Size (mm2)
    • Output Wire Size (mm2)
    • Max. Positive Input Wire Size (mm2)
    • Max. Negative Input Wire Size (mm2)
    • Combiner Negative Output Wire Size (mm2)
    • Combiner Input Wire Size (mm2)
    • Combiner Enclosure Rating
    • Combiner Maximum Input Fuse Rating (A)
    • Combiner Operating Temperature (CËš)
    • Cables
    • Reel Length (Imperial)
    • Cable (Wire) Size [mm² (AWG)]
    • Jacket Color
    • Cable Conductor Material
    • Cable Voltage Rating [V]
    • Breakers
    • Circuit Breaker Amps [A]
    • Poles
    • AC Voltage Rating [Vac]
    • DC Voltage Rating [Vdc]
    • FusedNo
    No Reviews Available.