Home > Newest Products: Energy Storage > Products > Monitoring > 

SOLAR-LOG 300 Monitoring Data Logger, Max Power 15kW

SOLAR-LOG 300 Monitoring Data Logger, Max Power 15kW

    Solar Data Systems, Inc. (SolarLog) SKU#: SolarLog 300
    Review(s)

    About This Product

      add to project
      You must be logged in to Add to Project.
      • features
      • Videos
      • Downloads
      • Related Items
      • Learn
      • Reviews
      SOLAR-LOG 300 Monitoring Data Logger compatible with all the major inverters. Unlimited number of inverters from one manufacturer, maximum total power of 15 kWp. Free online monitoring. 5 Years Warranty. 

      The low cost failure and yield monitoring system for plants with a maximum power of 15 kWp. Includes alarm function and graphic evaluation on PC.

      Plants size
      The Solar-Log 300 can be installed in plants with a maximum total power of 15 kWp, regardless of the number of inverters. Therefore, this new model can monitor smaller plants with two or three inverters of the same manufacturers without any problems.


      Using self-produced power
      The Solar-Log 300 is available in the Solar-Log 300 meters version, which has an integrated electricity meter. This saves a considerable amount of installation time and costs. 
      The Solar-Log® Meter can monitor up to 2 individual or coupled three-phrase cables.  Additional external electricity meters can be connected to the two S0 inputs. Small appliances such as freezers and laundry dryers can be monitored and controlled via a networked "smart plug", a device that fits on top of existing electrical outlets. The smart plugs measure the power consumption of the device connected to the socket and send this data to the Solar-Log®. As a result, every individual smart plug can be displayed in the graphic with the total consumption.


      Feed-in management
      Of course, power management has been taken into account with all of the new models. The intelligent management of the 70% regulation is rather attractive for small plants. The Solar-Log can help to further optimize the share of self-produced power.  There is also an option to buy the Solar-Log 300 with the well-established Power Management function (PM+) for the connection to a ripple control receiver.



      Free Online Monitoring
      Solar-Log Web Classic 2nd Edition offers all of the basic functions for monitoring and analyzing status messages. The yields and reports are graphically presented. The ”Classic 2nd Edition“ is free of charge up to 30 kWp.















      Product Specifications

      • Characteristics
      • ManufacturerSolar Data Systems, Inc. (SolarLog)
      • ModelSolar-Log 300
      • Other Vendor Codes
      • Rated Power Output [W]
      • Length [mm (in)]285 mm
      • Width [mm (in)]225 mm
      • Depth [mm (in)]40 mm
      • Weight [kg (lb)]
      • Warranty [Years]5
      • Surge/Lightning Protection
      • Maximum Volts [Vdc]
      • Discharge Current [kA]
      • Nominal DC Voltage Range [Vdc]
      • Nominal AC Voltage [Vac]
      • Modules
      • PTC Power Rating [W]
      • Tier Level
      • Lower Output Tolerance [-%]
      • Upper Output Tolerance [%]
      • Only suitable for transformer invertersNo
      • Compatible with IronRidge CAMO No
      • Pmax - Maximum Power (STC) [W]
      • Voc - Open Circuit Voltage (STC) [V]
      • Isc - Short Circuit Current (STC) [A]
      • Vmpp-Voltage at Maximum Power (STC) [V]
      • Impp-Current at Maximum Power (STC) [A]
      • Cell Efficiency (STC) [%]
      • Module Efficiency (STC) [%]
      • Pmax - Maximum Power (NOCT) [W]
      • Voc - Open Circuit Voltage (NOCT) [V]
      • Isc - Short Circuit Current (NOCT) [A]
      • Impp-Current at Maximum Power (NOCT) [A]
      • Vmpp-Voltage at Maximum Power (NOCT) [V]
      • Cell Efficiency (NOCT) [%]
      • Module Efficiency (NOCT) [%]
      • Nominal Operating Cell Temperature NOCT
      • Maximum System Voltage [V]
      • Series Fuse Rating [A]
      • Maximum Reverse Current [A]
      • Cell Technology
      • Solar Cell's Country of Origin
      • Solar Cell Size
      • Number of Cells (Pieces)
      • Number of Bypass Diodes
      • Frame Color
      • Back Cover
      • Frame Size [mm]
      • Module Length [in]
      • Module Width [in]
      • Junction Box
      • Output Cables
      • Connector
      • Hail Safety Impact Velocity [mm at m/s]
      • Fire Safety Classification (IEC 61730)
      • Static Load Wind / Snow [Pa]
      • Normal Operating Cell Temperature (NOCT)
      • Temperature Coefficients of P [%/°C]
      • Temperature Coefficients of V (Uoc)
      • Temperature Coefficients of I (Isc)
      • Storage Temperature [°C]
      • Packaging Configuration
      • Loading Capacity (40 ft. Container)
      • 80% Power Output Warranty Period
      • 90% Power Output Warranty Period
      • Workmanship Warranty Period
      • CSI Listed
      • Inverters
      • Inverter Type
      • Maximum/Peak Efficiency [%]
      • CEC weighted efficiency [%]
      • Transformer / Transformerless
      • DC Power Rating [W]
      • Nom. DC Voltage [V]
      • Max. Input Power [W]
      • Max. Input Voltage [V]
      • Max. Input Current [A]
      • MPP voltage range [V]
      • Min. DC voltage / start voltage [V]
      • Feed-in From [W]
      • Number of DC String Inputs (Inlets)
      • Number of MPP Trackers
      • Max. Input Power per MPPT [W]
      • Max. Input Voltage per MPPT [V]
      • Max. Input Current per MPPT [A]
      • Voltage Lower Limit for MPP Range [V]
      • Voltage Upper Limit for MPP Range [V]
      • DC Disconnection Type
      • Reverse-Polarity ProtectionNo
      • Ground-Fault Isolation Detection
      • AC Power Rating [W]
      • Nominal AC Power [W]
      • Max. AC Power [W]
      • AC voltage range [V]
      • AC grid frequency [Hz]
      • Max. output current [A]
      • Nominal AC Voltage [V]
      • Maximum AC Voltage Range [V]
      • Nominal AC Frequency [Hz], range [Hz-Hz]
      • Max. AC Line Current [A]
      • AC Connection Type
      • AC Current Distortion [THD%]
      • AC DisconnectNo
      • AC Input Wire Gauge Range [AWG]
      • Max Microinverters Units per xA string
      • Sleep (Night) Consumption [W]
      • Standby Consumption [W]
      • CSI-Approved Built-in MeterNo
      • NEMA Enclosure Rating
      • Cooling Method
      • Ambient Temperature Range [°C(°F)]
      • Operating Humidity [%]
      • Operating Altitude [ft/m]
      • Display
      • Communication
      • Basic Warranty [Years]
      • Warranty Extension Options [Years]
      • Safety and EMC Standard
      • Grid Standard
      • Compliances
      • AC grid range [Hz]
      • Max. recommended PV power (@ module STC)
      • Fuses and Holders
      • Amps [A]
      • Data Logers
      • Bluetooth (BT)No
      • WiFi (wireless LAN)No
      • Powermanagement (PM+)No
      • Powermanagement (PM+) / GPRSNo
      • Powermanagement (PM+) / WiFiNo
      • GPRSNo
      • Central inverter SCB and SMBNo
      • Max. no. inverters
      • Communication interface1 x RS485 / RS422 (1 inv. manufacturer perbus)
      • Inverter mixed operationNo
      • Measured max. plant size [kWp]15
      • Max. cable lengthMax. 1000m
      • String monitoring-depends on inv. modelYes
      • Inverter failureYes
      • Performance monitoring for each inverterYes
      • Status/fault monitoringYes
      • Connection to sensor systemYes
      • Connection to Sensor BasicYes
      • Email and SMS alarmYes
      • Local alarm (pot. free contact)No
      • Yield forecastingNo
      • Degradation calculationYes
      • Connection to digital meter readerYes
      • Integrated webserverYes
      • Graphic visualisation - local PCYes
      • Graphic visualisation - USB stickNo
      • Graphic visualisation - internetYes
      • LED status displayYes
      • Operation on deviceNo
      • Large display RS485/S0 pulseYes
      • Sâ‚€ in/out+/-
      • Ethernet networkYes
      • USB stickNo
      • Analogue modem / GPRS(GSM)No
      • Potential-free contact (relay)No
      • Alarm contact (anti-theft)No
      • Mains voltage / device voltage [Vac/Vdc]115 V – 230 V/ 12 V
      • Power consumption [W]3
      • Ambient Temperature [°C(°F)]-10°C to +50°C
      • Assemblywall-mounted
      • Protection class for loggerIP 20 (for inside use only)
      • Connection to Solar-LogTM WEBYes
      • Multilingual (DE, EN, ES, FR, IT, NL)Yes
      • Memory
      • Connectors
      • Pre-configured (p), Configurable (c)
      • Test Specifications
      • LockableNo
      • Protection Type Connected / Disconnected
      • Approved Temperature Range [°C]
      • Rated Current, Specified Cable Cross-sec
      • Contact Resistance [mΩ]
      • Max. System DC Voltage [V]
      • Protection Class
      • Contact Material
      • Plug Face is Similar to
      • Combinable w original type confirmed by
      • Measurements (length x cross-section)
      • Combiners
      • Usable Cable Cross-section
      • Number of Breakers
      • Number of Fuse Holders
      • Combiner Voltage Rating (VDC)
      • Combiner Maximum DC Current (A)
      • Max. Input Short Cir. Current/String [A]
      • Maximum Continuous Current (A)
      • Max. Input Current Per String (A)
      • Combiner Maximum Voltage (VDC)
      • Combiner Positive Output Wire Size (mm2)
      • Output Wire Size (mm2)
      • Max. Positive Input Wire Size (mm2)
      • Max. Negative Input Wire Size (mm2)
      • Combiner Negative Output Wire Size (mm2)
      • Combiner Input Wire Size (mm2)
      • Combiner Enclosure Rating
      • Combiner Maximum Input Fuse Rating (A)
      • Combiner Operating Temperature (CËš)
      • Cables
      • Reel Length (Imperial)
      • Cable (Wire) Size [mm² (AWG)]
      • Jacket Color
      • Cable Conductor Material
      • Cable Voltage Rating [V]
      • Breakers
      • Circuit Breaker Amps [A]
      • Poles
      • AC Voltage Rating [Vac]
      • DC Voltage Rating [Vdc]
      • FusedNo
      • Wireless Characteristics
      • Frequency (GHz) 
      • Output Power (dBm)
      • Throughput (Gbps)
      • Range
      • Min Gain (dBi)
      • Max Gain (dBi)
      • Antenna Type 
      • Number of Antennas
      • Antenna Beamwidth - Azimuth (H) (Degrees)
      • Antenna Beamwidth - Elevation (V) (Degrees)
      • Electrical Beamwidth (Degrees)
      • Polarization 
      • Port to Port Isolation (dB)
      • Min Cross Pol Isolation (dB)
      • Cross Pol Isolation (dB)
      • Front to Back Ratio (dB)
      • PTP or PTMP 
      • Licensed 
      • Wireless Integrated System?
      • WiFi Connector
      • Wireless Connector 
      • Number of Connectors
      • Electrical Tilt Type 
      • Min Electrical Tilt (Degrees)
      • Max Electrical Tilt (Degrees)
      • Mechanical Tilt Type 
      • Min Mechanical Tilt (Degrees)
      • Max Mechanical Tilt (Degrees)
      • Lens
      • Sensor
      • Mounting 
      • Power Method 
      • Voltage
      • PoE Interfaces 
      • PoE Adapter IncludedNo
      • Wireless Technology
      • MiMo
      • Surge Suppression
      • WiFi Standard 
      • Min Concurrent Clients
      • Concurrent Clients
      • Channel Spacing
      • Max Transmit Power (dBm)
      • Video
      • Video Compression 
      • Resolution 
      • Max Frame Rate
      • Image Setting 
      • Night Mode 
      • Microphone
      • View Angle (degree)
      • Switches
      • Switching Capacity (Gbps)
      • Total Non Blocking Throughput
      • Forwarding Rate (MPPS)
      • Ports 
      • No. of Data Ports
      • Regulatory / Compliance Info
      • FCC Regulations 
      • Certifications / Wireless Approval
      • Building Materials
      • Knockout Size (Inch)
      • Outside Diameter (Inch)
      • Inside Diameter (Inch)
      • Wall Thickness (Inch)
      • Material
      • Color
      • Exposure (Inch)
      • Shingles Per Square
      • Wind Resistance (mph)
      • Maximum plant size: 15 kWp
      • Optional Powermanagement
      • LCD Status Display
      • Monitor, optimize and manage the consumption of self-produced power
      • 2x S0 in (1 additional)
      • 1x USB
      • Number of inverters: unlimited from one manufacturer
      • Optional features: WiFi, Bluetooth, GPRS, PM+, PM+/WiFi, PM+/GPRS, Meter
      Functions
      So small and yet so many functions: The Solar-Log 300 is a yield evaluation tool, an alarm system and a forecasting tool all in one device.

      Connections

      Inverters
      The Solar-Log 300 is compatible with all the major inverters. It can be connected to an unlimited number of inverters from one manufacturer with a maximum total power of 15 kWp.

      Sensors RS485
      The sensors measure irradiation, temperature and wind speed. However, they cannot be combined with every inverter manufacturer.

      Meter S0-in or RS485
      The meter records your consumption data, can serve as an inverter or measures the power from incompatible inverters.

      RS485 or S0-out
      Connect large displays to obtain an overview of your data.

      Ripple Control Receiver
      The signal to reduce active power is generally sent via a Ripple Control Receiver. This can be connected directly to the Solar-Log 300 PM+ to control the power of the PV plant.

      Solar-Log 300 USB connection and Data Export
      A USB stick can be connected to manually install new firmwares with additional inverter support or new functions, or to transfer backups and other data.


      Visualization

      Solar-Log® WEB
      The Solar-Log® WEB ”Commercial Edition“ online portal expands the monitoring function of the Solar-Log® and offers comprehensive monitoring reporting options in the form of graphs and tables via the internet.

      lSolar-Log® APP
      You can access your data and graphical reports at any time from anywhere in the world with the Solar-Log® APP.

      Solar-Log® Dashboard
      A feature with the WEB ”Commercial Edition“ is that the Dashboard displays all important information for a plant such as yields, CO2 savings and plant performance.

      Solarfox® large display and external displays
      A large display used in combination with the Solar-Log® can visually present the live data from a PV plant. You can also add personalized advertisements. External displays can be connected via the RS485 or S0 interface.

      Accessing the Solar-Log®
      The Solar-Log® is operated from a PC with any standard web browser and via the TFT display. Remote access is possible with the WEB ”Commercial Edition“.


      Options
      Solar-Log 300 GPRS 
      Solar-Log 300 GPRS is the alternative to an external GPRS modem, allowing the data logger to be connected to the data network simply and securely. A GPRS connection is especially suited to free-standing plants or buildings which do not have a usable internet connection available.

      Solar-Log 300 WiFi
      The Solar-Log 300 WiFi allows you to connect the Solar-Log® to any available WiFi network. This saves cables, installations time and reduces labor costs.

      Solar-Log 300 Bluetooth
      This data logger is equipped with a Bluetooth module and allows wireless connection to SMA BT inverters, up to a maximum of seven.

      Solar-Log 300 PM+
      The PM+ product line implements the feed-in and network safety management. It covers the entire spectrum of requirements for active and reactive power, e.g. the German Renewable Energy Law 2012 (EEG).

      Solar-Log 300 Meter
      The Solar-Log® Meter makes it possible to monitor a PV plant completely and to measure its power consumption with just one device. With 2 x 1 to 3-phase current measurements, it determines the active power for production and self-consumption.


      Functions


      Solar-Log® Easy Installation
      The installation and initial setup start automatically. The inverter detection and the internet log-on starts immediately. The installation status is shown on the LCD display. Any subsequent manual configurations of the Solar-Log® can be performed conveniently from a PC via the WEB interface. Easy Installation is compatible with the Solar-Log® WEB ”Commercial Edition“ and ”Classic 2nd Edition“.

      Self-consumption
      The Solar-Log 300 offers the option to measure the amount of self-produced power consumed and to present it graphically via the Solar-Log® WEB. A digital power meter serves as a consumption meter. Thanks to the new Solar-Log® Meter, no additional electricity meter is needed as it is already integrated in the device.

      Data security
      The data volume from the Solar-Log® can be recorded for up to 20 years. The micro SD card is used to protect against any loss of data in the event of a power failure.

      Related Items

      Other customers also bought

      MULTI-CONTACT MC4 FEMALE Cable Coupler PV-KBT4/6II-UR
      MULTI-CONTACT MC4 FEMALE Cable Coupler PV-KBT4/6II-UR
      Price: Please, login or register to see prices.
      MULTI-CONTACT MC4 MALE Cable Coupler PV-KST4/6II-UR
      MULTI-CONTACT MC4 MALE Cable Coupler PV-KST4/6II-UR
      Price: Please, login or register to see prices.
      SOLAR-LOG 1200 Monitoring Data Logger, Max Power 100kW
      SOLAR-LOG 1200 Monitoring Data Logger, Max Power 100kW
      Price: Please, login or register to see prices.
      HELLERMANN TYTON Solar Label CAUTION:PV SYSTEM BACKFED Qty1
      HELLERMANN TYTON Solar Label CAUTION:PV SYSTEM BACKFED Qty1
      Price: Please, login or register to see prices.
      HELLERMANN TYTON Solar Label DUAL POWER SOURCE Qty1
      HELLERMANN TYTON Solar Label DUAL POWER SOURCE Qty1
      Price: Please, login or register to see prices.
      HELLERMANN TYTON Pre-Printed Solar Label, AC DISCONNECT WARN
      HELLERMANN TYTON Pre-Printed Solar Label, AC DISCONNECT WARN
      Price: Please, login or register to see prices.
      HELLERMANN TYTON Solar Label WARNING - ELECTRIC SHOCK Qty1
      HELLERMANN TYTON Solar Label WARNING - ELECTRIC SHOCK Qty1
      Price: Please, login or register to see prices.
      RENVU MEGA-WATT Annual Membership Renewal
      RENVU MEGA-WATT Annual Membership Renewal
      Price: Please, login or register to see prices.

      Ask a Question

      No Reviews Available.
      Please, login or register to see prices.

      Don't see prices? Sign In or Register
      • Est. Ship Out Time: 5 Days
      • Min. Qty Order:
      • Sold in Quantities Of:
      • Note:
      • Select Project
      Create Projects
      This is helpful for many reasons. The project page will contain additional information, such as relevant data sheets and videos. You will be able to re-use the project items in future projects. It will also create a quote on our back end, for better collaboration with the RENVU team.

      SOLAR-LOG 300 Monitoring Data Logger, Max Power 15kW

      Price: Please, login or register to see prices.

      Average Rating

      ()

      Product Features

      SOLAR-LOG 300 Monitoring Data Logger compatible with all the major inverters. Unlimited number of inverters from one manufacturer, maximum total power of 15 kWp. Free online monitoring. 5 Years Warranty. 

      The low cost failure and yield monitoring system for plants with a maximum power of 15 kWp. Includes alarm function and graphic evaluation on PC.

      Plants size
      The Solar-Log 300 can be installed in plants with a maximum total power of 15 kWp, regardless of the number of inverters. Therefore, this new model can monitor smaller plants with two or three inverters of the same manufacturers without any problems.


      Using self-produced power
      The Solar-Log 300 is available in the Solar-Log 300 meters version, which has an integrated electricity meter. This saves a considerable amount of installation time and costs. 
      The Solar-Log® Meter can monitor up to 2 individual or coupled three-phrase cables.  Additional external electricity meters can be connected to the two S0 inputs. Small appliances such as freezers and laundry dryers can be monitored and controlled via a networked "smart plug", a device that fits on top of existing electrical outlets. The smart plugs measure the power consumption of the device connected to the socket and send this data to the Solar-Log®. As a result, every individual smart plug can be displayed in the graphic with the total consumption.


      Feed-in management
      Of course, power management has been taken into account with all of the new models. The intelligent management of the 70% regulation is rather attractive for small plants. The Solar-Log can help to further optimize the share of self-produced power.  There is also an option to buy the Solar-Log 300 with the well-established Power Management function (PM+) for the connection to a ripple control receiver.



      Free Online Monitoring
      Solar-Log Web Classic 2nd Edition offers all of the basic functions for monitoring and analyzing status messages. The yields and reports are graphically presented. The ”Classic 2nd Edition“ is free of charge up to 30 kWp.















      Product Specifications

      Downloads

        Videos

        Related Items

        Learn

        Ask a Question

        People Also Bought

        http://www.renvu.com/Solar-Log300-174pxl.jpg
        SOLAR-LOG 300 Monitoring Data Logger, Max Power 15kW
        SOLAR-LOG 300 Monitoring Data Logger compatible with all the major inverters. Unlimited number of inverters from one manufacturer, maximum total power of 15 kWp. Free online monitoring. 5 Years Warranty.
        Please, login or register to see prices.
        Solar Data Systems, Inc. (SolarLog)
        Solar-Log 300
        285 mm
        225 mm
        40 mm
        No
        No
         
         
         
         
         
         
         
         
         
         
         
         